Electrical contracting for LV and MV systems
From design to fabrication, from switchgear assembly to interior works, we run electrical scopes to regulation and keep the records.
- Every scale, from housing to industrial plants
- Compliance with the relevant regulations and specifications
- Site work fully aligned with OHS rules
Electrical work is the most expensive thing to correct afterwards
Decisions like cable sizing, protection discrimination, earthing and panel layout cannot be changed once execution starts — and when they are, the cost is heavy. So we settle the design before going to site, and put the material list and work sequence in writing.
We provide design, fabrication and installation for low-voltage (LV) and medium-voltage (MV) systems. Electrical installation, distribution panel assembly, indoor and outdoor lighting and earthing works are carried out to the relevant regulations with auditable quality control. We work at every scale, from housing to industrial plants.
- Design and material list settled up front
- Protection discrimination and earthing calculations
- Fabrication progressed with interim inspections
- Measurement and test records at handover
What our electrical contracting covers
Depending on the job we can take on fabrication only, or run turnkey from design through commissioning.
- 01
LV distribution systems
Low-voltage distribution network, main and sub-panel connections, riser circuits and supply infrastructure.
- 02
MV systems and substations
Medium-voltage cells, substation connections and the construction of underground MV cable routes.
- 03
Panel manufacture and assembly
Distribution, power-factor correction and control panels built to design, assembled on site and commissioned.
- 04
Building electrical installation
Cable tray and conduit systems, socket and lighting circuits, floor panels and interior electrical works.
- 05
Earthing and lightning protection
Earthing installation, equipotential bonding and lightning protection systems, installed and measured.
- 06
Indoor and outdoor lighting
Illuminance calculation, luminaire selection and mounting; poles and supply for road, park and garden lighting.
- 07
Measurement, testing and commissioning
Insulation, continuity and earthing measurements; functional tests and handover of acceptance documentation.
A few lines are enough for a survey and a quote
Leave your number and we will call back the same day. The survey is free; the quotation comes itemised, with quantities and lead times.
- Free site survey
- Itemised, transparent quotation
- One contact, one schedule
From design to acceptance
- 01
Survey and scope definition
We see the site, record the existing condition and put the work to be done in writing, item by item.
- 02
Design and material selection
Electrical design, load calculations and the material list are prepared; supply starts once you approve.
- 03
Fabrication and installation
Site work runs to the programme, progressing with interim inspections and quality-control records.
- 04
Testing, acceptance and handover
Measurements are taken, the snag list is closed, and documentation and acceptance papers are handed over.
Our working range
- Voltage levels
- Low voltage (LV) and medium voltage (MV)
- Panel types
- Distribution, power-factor correction, control and automation panels
- Installation works
- Cable tray, conduit, riser circuits, floor panels
- Protection
- Earthing, equipotential bonding, lightning protection
- Measurement and testing
- Insulation, continuity, earth resistance, functional tests
- Deliverables
- Measurement reports, as-built drawings, acceptance documentation
Who is it for?
LV and MV systems, electrical installation, switchgear manufacture and lighting works.
Get a Quote- Housing and estate projects
- Offices and business centres
- Retail and commercial spaces
- Factories and production plants
- Warehouses and logistics buildings
- Public buildings
From work completed on site
-
7.2 kW Off-Grid Solar Energy System A 7.2 kW rooftop installation that never touches the grid and stores what it generates in a lithium battery. Gölbaşı / Ankara -
3 kW Off-Grid System for a Country House A 3 kW off-grid system on the trapezoidal metal roof of a single-storey house away from the grid. Kahramankazan / Ankara -
3 kW Off-Grid System at a Greenhouse Operation A ground-fixed 3 kW off-grid system built for the energy needs of a greenhouse operation. Akdağmadeni / Yozgat
Frequently asked
-
Yes. Where a design already exists we can work to an installation-only scope. Where there is no design we recommend preparing one first — most site surprises originate there.
-
Cable sizing, suitability of protective devices, earth measurements and panel condition are assessed on site. After the survey we report what is mandatory and what is an improvement, separately.
-
Distribution, correction and control panels are built to the design, then assembled and commissioned on site by our team. Product supply can come through the same scope.
-
Full compliance with OHS legislation, personal protective equipment and regular risk assessment are mandatory on all our sites. Lock-out/tag-out procedures apply wherever live working is involved.
Headings that may help in the same project
-
Engineering & Design Electrical, mechanical, structural and architectural design; connection and capacity increase. Service detail -
Solar Energy Systems Solar design, installation, storage and EV charging — from feasibility to commissioning. Service detail -
Permits & Construction Drawings Permit designs, construction drawings and authority follow-up. Service detail
- LV Systems
- MV Systems
- Switchgear
- Earthing
- Power Factor Correction
- Cable Tray
- Electrical Contracting
One point of contact from survey through to commissioning. Tell us what you need and we will define the scope together.
- Call us +90 532 309 99 40
- Send an e-mail info@bkdmuhendislik.com.tr
- Message on WhatsApp +90 532 309 99 40
- Mon – Sat · 08:00 – 18:00